Many experiments have documented the response of intraocular pressure (IOP) to postural change. External forces caused by gravitational orientation change produce a dynamic response that is encountered every day during normal activities. Tilting the body at a small downward angle is also relevant to studying the effects of hypogravity (spaceflight), including ocular changes. We examined data from 36 independent datasets from 30 articles on IOP response to postural change, representing a total population of 821 subjects (≥1173 eyes) with widely varying initial and final postures. We confirmed that IOP was well predicted by a simple quantity, namely the hydrostatic pressure at the level of the eye, although the dependence was complex (nonlinear). Our results show that posturally induced IOP change can be explained by hydrostatic forcing plus an autoregulatory contribution that is dependent on hydrostatic effects. This study represents data from thousands of IOP measurements and provides insight for future studies that consider postural change in relation to ocular physiology, intraocular pressure, ocular blood flow and aqueous humor dynamics.
Pathologic changes in intracranial pressure (ICP) are commonly observed in a variety of medical conditions, including traumatic brain injury, stroke, brain tumors, and glaucoma. However, current ICP measurement techniques are invasive, requiring a lumbar puncture or surgical insertion of a cannula into the cerebrospinal fluid (CSF)-filled ventricles of the brain. A potential alternative approach to ICP measurement leverages the unique anatomy of the central retinal vein, which is exposed to both intraocular pressure (IOP) and ICP as it travels inside the eye and through the optic nerve; manipulating IOP while observing changes in the natural pulsations of the central retinal vein could potentially provide an accurate, indirect measure of ICP. As a step toward implementing this technique, we describe the design, fabrication, and characterization of a system that is capable of manipulating IOP in vivo with <0.1 mmHg resolution and settling times less than 2 seconds. In vitro tests were carried out to characterize system performance. Then, as a proof of concept, we used the system to manipulate IOP in tree shrews (Tupaia belangeri) while video of the retinal vessels was recorded and the caliber of a selected vein was quantified. Modulating IOP using our system elicited a rapid change in the appearance of the retinal vein of interest: IOP was lowered from 10 to 3 mmHg, and retinal vein caliber sharply increased as IOP decreased from 7 to 5 mmHg. Another important feature of this technology is its capability to measure ocular compliance and outflow facility in vivo, as demonstrated in tree shrews. Collectively, these proof-of-concept demonstrations support the utility of this system to manipulate IOP for a variety of useful applications in ocular biomechanics, and provide a framework for further study of the mechanisms of retinal venous pulsation.