Skip to navigation Skip to content
  • Woodruff
  • Business
  • Health Sciences
  • Law
  • MARBL
  • Oxford College
  • Theology
  • Schools
    • Undergraduate

      • Emory College
      • Oxford College
      • Business School
      • School of Nursing

      Community

      • Emory College
      • Oxford College
      • Business School
      • School of Nursing
    • Graduate

      • Business School
      • Graduate School
      • School of Law
      • School of Medicine
      • School of Nursing
      • School of Public Health
      • School of Theology
  • Libraries
    • Libraries

      • Robert W. Woodruff
      • Business
      • Chemistry
      • Health Sciences
      • Law
      • MARBL
      • Music & Media
      • Oxford College
      • Theology
    • Library Tools

      • Course Reserves
      • Databases
      • Digital Scholarship (ECDS)
      • discoverE
      • eJournals
      • Electronic Dissertations
      • EmoryFindingAids
      • EUCLID
      • ILLiad
      • OpenEmory
      • Research Guides
  • Resources
    • Resources

      • Administrative Offices
      • Emory Healthcare
      • Academic Calendars
      • Bookstore
      • Campus Maps
      • Shuttles and Parking
      • Athletics: Emory Eagles
      • Arts at Emory
      • Michael C. Carlos Museum
      • Emory News Center
      • Emory Report
    • Resources

      • Emergency Contacts
      • Information Technology (IT)
      • Outlook Web Access
      • Office 365
      • Blackboard
      • OPUS
      • PeopleSoft Financials: Compass
      • Careers
      • Human Resources
      • Emory Alumni Association
  • Browse
    • Works by Author
    • Works by Journal
    • Works by Subject
    • Works by Dept
    • Faculty by Dept
  • For Authors
    • How to Submit
    • Deposit Advice
    • Author Rights
    • Publishing Your Data
    • FAQ
    • Emory Open Access Policy
    • Open Access Fund
  • About OpenEmory
    • About OpenEmory
    • About Us
    • Citing Articles
    • Contact Us
    • Privacy Policy
    • Terms of Use
 
Contact Us

Filter Results:

Year

  • 2012 (2)
  • 2013 (1)
  • 2015 (1)
  • 2017 (1)

Author

  • Yoganathan, Ajit (5)
  • Fogel, Mark (2)
  • Fogel, Mark A. (2)
  • Haggerty, Christopher M. (2)
  • Khiabani, Reza H. (2)
  • Tang, Elaine (2)
  • Chaffins, Brandon D. (1)
  • Dasi, Lakshmi P. (1)
  • De Zelicourt, Diane (1)
  • Frakes, David H. (1)
  • Kanter, Kirk R (1)
  • Mirabella, Lucia (1)
  • Okafor, Ikechukwu U. (1)
  • Oshinski, John (1)
  • Pekkan, Kerem (1)
  • Powell, Andrew J. (1)
  • Restrepo, Maria (1)
  • Santhanakrishnan, Arvind (1)
  • Sotiropoulos, Fotis (1)
  • Sundareswaran, Kartik S. (1)
  • Tree, Mike (1)
  • Trusty, Phillip M. (1)
  • Wei, Zhenglun (Alan) (1)
  • de Zelicourt, Diane (1)

Subject

  • Engineering, Biomedical (4)
  • Health Sciences, Medicine and Surgery (2)
  • Health Sciences, Radiology (2)
  • Biophysics, General (1)
  • Engineering, Chemical (1)

Journal

  • Circulation: Cardiovascular Imaging (1)
  • Journal of Biomechanical Engineering (1)
  • Journal of Biomechanics (1)
  • Journal of Cardiovascular Magnetic Resonance (1)
  • Journal of Thoracic and Cardiovascular Surgery (1)

Keyword

  • biomedicin (5)
  • life (5)
  • scienc (5)
  • cavopulmonari (4)
  • comput (4)
  • connect (4)
  • fluid (4)
  • total (4)
  • cardiac (3)
  • cardiolog (3)
  • cardiovascular (3)
  • exercis (3)
  • interpol (3)
  • magnet (3)
  • reson (3)
  • simul (3)
  • system (3)
  • anatomi (2)
  • biomed (2)
  • biophys (2)
  • engin (2)
  • flow (2)
  • fluiddynam (2)
  • fontan (2)
  • hemodynam (2)
  • imag (2)
  • malform (2)
  • medic (2)
  • medicin (2)
  • nuclear (2)
  • procedur (2)
  • radiolog (2)
  • arterioven (1)
  • arteriovenousmalform (1)
  • blood (1)
  • bloodflow (1)
  • boundari (1)
  • condit (1)
  • echocardiographi (1)
  • failur (1)
  • format (1)
  • fsi (1)
  • heart (1)
  • heartfailur (1)
  • in (1)
  • intraatri (1)
  • invitro (1)
  • left (1)
  • magneticreson (1)
  • model (1)
  • mr (1)
  • oper (1)
  • palliat (1)
  • particl (1)
  • patient (1)
  • patientspecif (1)
  • phantom (1)
  • phase (1)
  • photogrammetri (1)
  • plan (1)
  • pulmonari (1)
  • pulsatil (1)
  • quantif (1)
  • respiratori (1)
  • segment (1)
  • specif (1)
  • stereo (1)
  • stereophotogrammetri (1)
  • surgeri (1)
  • surgic (1)
  • univentricular (1)
  • valid (1)
  • velocimetri (1)
  • ventricl (1)
  • vitro (1)
  • vortex (1)

Author department

  • BME: Admin (5)
  • Rad: MR Research Lab (1)
  • Surgery: Thoracic (1)

Search Results for all work with filters:

  • dynam
  • reconstruct
  • technolog

Work 1-5 of 5

Sorted by relevance

Article

Can time-averaged flow boundary conditions be used to meet the clinical timeline for Fontan surgical planning?

by Zhenglun (Alan) Wei; Phillip M. Trusty; Mike Tree; Christopher M. Haggerty; Elaine Tang; Mark Fogel; Ajit Yoganathan

2017

Subjects
  • Engineering, Biomedical
  • File Download
  • View Abstract

Abstract:Close

Cardiovascular simulations have great potential as a clinical tool for planning and evaluating patient-specific treatment strategies for those suffering from congenital heart diseases, specifically Fontan patients. However, several bottlenecks have delayed wider deployment of the simulations for clinical use; the main obstacle is simulation cost. Currently, time-averaged clinical flow measurements are utilized as numerical boundary conditions (BCs) in order to reduce the computational power and time needed to offer surgical planning within a clinical time frame. Nevertheless, pulsatile blood flow is observed in vivo, and its significant impact on numerical simulations has been demonstrated. Therefore, it is imperative to carry out a comprehensive study analyzing the sensitivity of using time-averaged BCs. In this study, sensitivity is evaluated based on the discrepancies between hemodynamic metrics calculated using time-averaged and pulsatile BCs; smaller discrepancies indicate less sensitivity. The current study incorporates a comparison between 3D patient-specific CFD simulations using both the time-averaged and pulsatile BCs for 101 Fontan patients. The sensitivity analysis involves two clinically important hemodynamic metrics: hepatic flow distribution (HFD) and indexed power loss (iPL). Paired demographic group comparisons revealed that HFD sensitivity is significantly different between single and bilateral superior vena cava cohorts but no other demographic discrepancies were observed for HFD or iPL. Multivariate regression analyses show that the best predictors for sensitivity involve flow pulsatilities, time-averaged flow rates, and geometric characteristics of the Fontan connection. These predictors provide patient-specific guidelines to determine the effectiveness of analyzing patient-specific surgical options with time-averaged BCs within a clinical time frame.

Article

Visualization of flow structures in Fontan patients using 3-dimensional phase contrast magnetic resonance imaging

by Kartik S. Sundareswaran; Christopher M. Haggerty; Diane de Zelicourt; Lakshmi P. Dasi; Kerem Pekkan; David H. Frakes; Andrew J. Powell; Kirk R Kanter; Mark A. Fogel; Ajit Yoganathan

2012

Subjects
  • Health Sciences, Medicine and Surgery
  • Engineering, Biomedical
  • File Download
  • View Abstract

Abstract:Close

Objective: Our objective was to analyze 3-dimensional (3D) blood flow patterns within the total cavopulmonary connection (TCPC) using in vivo phase contrast magnetic resonance imaging (PC MRI). Methods: Sixteen single-ventricle patients were prospectively recruited at 2 leading pediatric institutions for PC MRI evaluation of their Fontan pathway. Patients were divided into 2 groups. Group 1 comprised 8 patients with an extracardiac (EC) TCPC, and group 2 comprised 8 patients with a lateral tunnel (LT) TCPC. A coronal stack of 5 to 10 contiguous PC MRI slices with 3D velocity encoding (5-9 ms resolution) was acquired and a volumetric flow field was reconstructed. Results: Analysis revealed large vortices in LT TCPCs and helical flow structures in EC TCPCs. On average, there was no difference between LT and EC TCPCs in the proportion of inferior vena cava flow going to the left pulmonary artery (43% ± 7% vs 46% ± 5%; P = .34). However, for EC TCPCs, the presence of a caval offset was a primary determinant of inferior vena caval flow distribution to the pulmonary arteries with a significant bias to the offset side. Conclusions: 3D flow structures within LT and EC TCPCs were reconstructed and analyzed for the first time using PC MRI. TCPC flow patterns were shown to be different, not only on the basis of LT or EC considerations, but with significant influence from the superior vena cava connection as well. This work adds to the ongoing body of research demonstrating the impact of TCPC geometry on the overall hemodynamic profile.

Article

Imaging for Preintervention Planning Pre- and Post-Fontan Procedures

by Mark A. Fogel; Reza H. Khiabani; Ajit Yoganathan

2013

Subjects
  • Health Sciences, Medicine and Surgery
  • Health Sciences, Radiology
  • File Download

Article

Effect of Flow Pulsatility on Modeling the Hemodynamics in the Total Cavopulmonary Connection

by Reza H. Khiabani; Maria Restrepo; Elaine Tang; Diane De Zelicourt; Fotis Sotiropoulos; Mark Fogel; Ajit Yoganathan

2012

Subjects
  • Engineering, Biomedical
  • Biophysics, General
  • File Download
  • View Abstract

Abstract:Close

Total cavopulmonary connection is the result of a series of palliative surgical repairs performed on patients with single ventricle heart defects. The resulting anatomy has complex and unsteady hemodynamics characterized by flow mixing and flow separation. Although varying degrees of flow pulsatility have been observed in vivo, non-pulsatile (time-averaged) boundary conditions have traditionally been assumed in hemodynamic modeling, and only recently have pulsatile conditions been incorporated without completely characterizing their effect or importance. In this study, 3D numerical simulations with both pulsatile and non-pulsatile boundary conditions were performed for 24 patients with different anatomies and flow boundary conditions from Georgia Tech database. Flow structures, energy dissipation rates and pressure drops were compared under rest and simulated exercise conditions. It was found that flow pulsatility is the primary factor in determining the appropriate choice of boundary conditions, whereas the anatomic configuration and cardiac output had secondary effects. Results show that the hemodynamics can be strongly influenced by the presence of pulsatile flow. However, there was a minimum pulsatility threshold, identified by defining a weighted pulsatility index (wPI), above which the influence was significant. It was shown that when wPI < 30%, the relative error in hemodynamic predictions using time-averaged boundary conditions was less than 10% compared to pulsatile simulations. In addition, when wPI < 50, the relative error was less than 20%. A correlation was introduced to relate wPI to the relative error in predicting the flow metrics with non-pulsatile flow conditions.

Article

Cardiovascular magnetic resonance compatible physical model of the left ventricle for multi-modality characterization of wall motion and hemodynamics

by Ikechukwu U. Okafor; Arvind Santhanakrishnan; Brandon D. Chaffins; Lucia Mirabella; John Oshinski; Ajit Yoganathan

2015

Subjects
  • Health Sciences, Radiology
  • Engineering, Biomedical
  • Engineering, Chemical
  • File Download
  • View Abstract

Abstract:Close

Background: The development of clinically applicable fluid-structure interaction (FSI) models of the left heart is inherently challenging when using in vivo cardiovascular magnetic resonance (CMR) data for validation, due to the lack of a well-controlled system where detailed measurements of the ventricular wall motion and flow field are available a priori. The purpose of this study was to (a) develop a clinically relevant, CMR-compatible left heart physical model; and (b) compare the left ventricular (LV) volume reconstructions and hemodynamic data obtained using CMR to laboratory-based experimental modalities. Methods: The LV was constructed from optically clear flexible silicone rubber. The geometry was based off a healthy patient's LV geometry during peak systole. The LV phantom was attached to a left heart simulator consisting of an aorta, atrium, and systemic resistance and compliance elements. Experiments were conducted for heart rate of 70 bpm. Wall motion measurements were obtained using high speed stereo-photogrammetry (SP) and cine-CMR, while flow field measurements were obtained using digital particle image velocimetry (DPIV) and phase-contrast magnetic resonance (PC-CMR). Results: The model reproduced physiologically accurate hemodynamics (aortic pressure = 120/80 mmHg; cardiac output = 3.5 L/min). DPIV and PC-CMR results of the center plane flow within the ventricle matched, both qualitatively and quantitatively, with flow from the atrium into the LV having a velocity of about 1.15 m/s for both modalities. The normalized LV volume through the cardiac cycle computed from CMR data matched closely to that from SP. The mean difference between CMR and SP was 5.5 ± 3.7 %. Conclusions: The model presented here can thus be used for the purposes of: (a) acquiring CMR data for validation of FSI simulations, (b) determining accuracy of cine-CMR reconstruction methods, and (c) conducting investigations of the effects of altering anatomical variables on LV function under normal and disease conditions.
Site Statistics
  • 30,271
  • Total Works
  • 7,571,522
  • Downloads
  • 188,461
  • Downloads This Year
  • 6,806
  • Faculty Profiles

Copyright © 2016 Emory University - All Rights Reserved
540 Asbury Circle, Atlanta, GA 30322-2870
(404) 727-6861
Privacy Policy | Terms & Conditions

v2.2.8-dev

Contact Us Recent and Popular Items
Download now