About this item:

43 Views | 23 Downloads

Author Notes:

Dahui Qin, dahui.qin@moffitt.org; Tel.: +1-8137-451-883

Conceptualization, D.Q.; methodology, D.Q., M.F., S.M.G., R.A., Z.Z., J.L. and K.L.; validation, D.Q., M.F., S.M.G., R.A., Z.Z., J.L. and K.L.; formal analysis, D.Q., M.F., S.M.G., R.A., Z.Z., J.L. and K.L.; investigation, D.Q., M.F., S.M.G., R.A., Z.Z., J.L. and K.L.; resources, S.M.G.; data curation, M.F., R.A., Z.Z., J.L. and K.L.; writing—original draft preparation, D.Q.; writing—review and editing, D.Q., M.F., S.M.G., R.A., Z.Z., J.L. and K.L.; visualization, D.Q. and M.F.; supervision, D.Q. and S.M.G.; project administration, D.Q. and S.M.G.; All authors have read and agreed to the published version of the manuscript.

The authors declare no conflict of interest.

Subject:

Research Funding:

This research received no external funding.

Keywords:

  • Science & Technology
  • Life Sciences & Biomedicine
  • Biochemistry & Molecular Biology
  • quality control
  • sample switch
  • sample contamination
  • sample error
  • DNA fingerprint
  • RESIDUAL DISEASE DETECTION
  • POLYMERASE-CHAIN-REACTION
  • QUALITY-CONTROL
  • EUROPE

Usage of DNA Fingerprinting Technology to Check Sample Error and Contamination in Molecular Laboratories

Tools:

Journal Title:

CURRENT ISSUES IN MOLECULAR BIOLOGY

Volume:

Volume 44, Number 11

Publisher:

, Pages 5543-5549

Type of Work:

Article | Final Publisher PDF

Abstract:

Sample identification error is a severe medical error in clinical molecular diagnostic laboratories, which can lead to reporting the wrong results for the patient involved. Sample contamination can also lead to incorrect test reports. Avoiding sample identification error and sample contamination could be life-saving. Sample switch and sample contamination could happen on laboratory bench works, especially when pipetting into multi-well plates. It is difficult to realize such errors during laboratory bench work. Laboratory staff may not be aware of such an error when it happens. DNA fingerprinting technology can be used to determine sample identity and subsequently identify sample switch and sample contamination in the laboratory. Our laboratory has explored the usage of this technology in our quality control process and successfully established that DNA fingerprinting can be used to monitor sample switch and sample contamination in next-generation sequencing and BCR/ABL1 real-time PCR bench work.

Copyright information:

© 2022 by the authors.

This is an Open Access work distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0/).
Export to EndNote