About this item:

400 Views | 358 Downloads

Author Notes:

Corresponding author: Sechopoulos, Ioannis, Working address: Department of Radiology and Nuclear Medicine, Radboud University Medical Centre, Geert Grooteplein 10, 6525 GA, Post 766, Nijmegen, The Netherlands, Ioannis.sechopoulos@radboudumc.nl, Telephone number: +31 24 366 80 89

Conflict of interest / Financial disclosures Sechopoulos, Ioannis Research Agreement, Siemens Speaking Agreement, Siemens Research Agreement, Toshiba Scientific Advisor, Fischer Imaging

Subjects:

Research Funding:

Supported in part by Grant No. R01CA163746 from the National Cancer Institute, National Institutes of Health and Grant No. IIR13262248 from the Susan G. Komen Foundation for the Cure.

The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Cancer Institute, the National Institutes of Health of the Komen Foundation.

Keywords:

  • Science & Technology
  • Life Sciences & Biomedicine
  • Radiology, Nuclear Medicine & Medical Imaging
  • breast modeling
  • breast phantoms
  • image segmentation
  • mammography
  • tomosynthesis
  • SCREENING MAMMOGRAPHY
  • DIGITAL TOMOSYNTHESIS
  • 3D SIMULATION
  • RADIATION
  • PHANTOM
  • DOSIMETRY
  • REGISTRATION
  • PERFORMANCE
  • UK

Improvements of an objective model of compressed breasts undergoing mammography: Generation and characterization of breast shapes

Tools:

Journal Title:

Medical Physics

Volume:

Volume 44, Number 6

Publisher:

, Pages 2161-2172

Type of Work:

Article | Post-print: After Peer Review

Abstract:

Purpose: To develop a set of accurate 2D models of compressed breasts undergoing mammography or breast tomosynthesis, based on objective analysis, to accurately characterize mammograms with few linearly independent parameters, and to generate novel clinically realistic paired cranio-caudal (CC) and medio-lateral oblique (MLO) views of the breast. Methods: We seek to improve on an existing model of compressed breasts by overcoming detector size bias, removing the nipple and non-mammary tissue, pairing the CC and MLO views from a single breast, and incorporating the pectoralis major muscle contour into the model. The outer breast shapes in 931 paired CC and MLO mammograms were automatically detected with an in-house developed segmentation algorithm. From these shapes three generic models (CC-only, MLO-only, and joint CC/MLO) with linearly independent components were constructed via principal component analysis (PCA). The ability of the models to represent mammograms not used for PCA was tested via leave-one-out cross-validation, by measuring the average distance error (ADE). Results: The individual models based on six components were found to depict breast shapes with accuracy (mean ADE-CC = 0.81 mm, ADE-MLO = 1.64 mm, ADE-Pectoralis = 1.61 mm), outperforming the joint CC/MLO model (P ≤ 0.001). The joint model based on 12 principal components contains 99.5% of the total variance of the data, and can be used to generate new clinically realistic paired CC and MLO breast shapes. This is achieved by generating random sets of 12 principal components, following the Gaussian distributions of the histograms of each component, which were obtained from the component values determined from the images in the mammography database used. Conclusion: Our joint CC/MLO model can successfully generate paired CC and MLO view shapes of the same simulated breast, while the individual models can be used to represent with high accuracy clinical acquired mammograms with a small set of parameters. This is the first step toward objective 3D compressed breast models, useful for dosimetry and scatter correction research, among other applications.

Copyright information:

© 2017 American Association of Physicists in Medicine.