In the following narrative review, we discuss the potential role of large language models (LLMs) in medical device innovation, specifically examples using generative pretrained transformer-4. Throughout the biodesign process, LLMs can offer prompt-driven insights, aiding problem identification, knowledge assimilation and decision-making. Intellectual property analysis, regulatory assessment and market analysis emerge as key LLM applications. Through case examples, we underscore LLMs’ transformative ability to democratise information access and expertise, facilitating inclusive innovation in medical devices as well as its effectiveness with providing real-time, individualised feedback for innovators of all experience levels. By mitigating entry barriers, LLMs accelerate transformative advancements, fostering collaboration among established and emerging stakeholders.
Purpose: To Evaluate the correlation between tumor dosimetric parameters with objective tumor response (OR) and overall survival (OS) in patients with surgically unresectable colorectal liver metastasis (CRLM) undergoing resin-based Ytrrium-90 selective internal radiation therapy (Y90 SIRT). Materials and Methods: 45 consecutive patients with CRLM underwent resin-based Y90 SIRT in one or both hepatic lobes (66 treated lobes total). Dose volume histograms were created with MIM Sureplan® v.6.9 using post-treatment SPECT/CT. Dosimetry analyses were based on the cumulative volume of the five largest tumors in each treatment session and non-tumoral liver (NTL) dose. Receiver operating characteristic (ROC) curve was used to evaluate tumor dosimetric factors in predicting OR by Response Evaluation Criteria for Solid Tumors at 3 months post-Y90. Additionally, ROC curve was used to evaluate non-tumoral liver dose as a predictor of grade ≥3 liver toxicity and radioembolization induced liver disease (REILD) 3 months post Y90. To minimize for potential confounding demographic and clinical factors, univariate and multivariate analysis of survival with mean tumor dose as one of the factors were also performed. Kaplan-Meier estimation was used for OS analysis from initial Y90 SIRT. Results: 26 out of 45 patients had OR with a median OS of 17.2 months versus 6.8 months for patients without OR (p < 0.001). Mean tumor dose (TD) of the five largest tumors was the strongest predictor of OR with an area under the curve of 0.73 (p < 0.001). Minimum TD, and TD to 30%, 50%, and 70% of tumor volume also predicted OR (p’s < 0.05). Mean TD ≥ 100 Gy predicted a significantly prolonged median OS of 19 vs. 11 months for those receiving.
A gravida 4 para 1021, 41-year-old woman postcaesarean section at 39 weeks and 1 day with clinically significant haemorrhage required embolisation of unique uterine arterial collaterals. She had persistent haemorrhage after initial bilateral uterine artery embolisation, and on further investigation she was found to have a hypertrophied right round ligament artery. Once successful embolisation of this abnormal right round ligament artery was completed using a combination of Gelfoam and coils, haemostasis was achieved. She had rapid clinical improvement, no complications and no further admissions on postprocedural follow-up over a year and a half later.
Purpose
This study aims to identify clinical and imaging prognosticators associated with the successful bridging or downstaging to liver transplantation (LT) in patients undergoing Yttrium-90 radioembolization (Y90-RE) for hepatocellular carcinoma (HCC).
Methods
Retrospectively, patients with Y90-RE naïve HCC who were candidates or potential candidates for LT and underwent Y90-RE were included. Patients were then divided into favorable (maintained or achieved Milan criteria (MC) eligibility) or unfavorable (lost eligibility or unchanged MC ineligibility) cohorts based on changes to their MC eligibility after Y90-RE. Penalized logistic regression analysis was performed to identify the significant baseline prognosticators.
Results
Between 2013 and 2018, 135 patients underwent Y90-RE treatment. Among the 59 (42%) patients within MC, LT eligibility was maintained in 49 (83%) and lost in 10 (17%) patients. Within the 76 (56%) patients outside MC, eligibility was achieved in 32 (42%) and unchanged in 44 (58%). Among the 81 (60%) patients with a favorable response, 16 (20%) went on to receive LT. Analysis of the baseline characteristics revealed that lower Albumin-Bilirubin score, lower Child–Pugh class, lower Barcelona Clinic Liver Cancer stage, HCC diagnosis using dynamic contrast-enhanced imaging on CT or MRI, normal/higher albumin levels, decreased severity of tumor burden, left lobe HCC disease, and absence of HBV-associated cirrhosis, baseline abdominal pain, or fatigue were all associated with a higher likelihood of bridging or downstaging to LT eligibility (p's < 0.05).
Conclusion
Certain baseline clinical and tumor characteristics are associated with the successful bridging or downstaging of potential LT candidates with HCC undergoing Y90-RE.
This report describes the case of a previously healthy 30-year-old woman who presented with uncontrolled hypertension and renal failure. This case emphasizes the importance of considering renal artery disease. The differential diagnosis for renal artery stenosis is discussed, and the diagnosis and management of Takayasu's arteritis in this patient are highlighted. (Level of Difficulty: Beginner.)
by
Mohammad Elsayed;
Mohammad Loya;
James Galt;
David Schuster;
Zachary Bercu;
Janice Newsome;
David Brandon;
Sonia Benenati;
Keywan Behbahani;
Richard Duszak;
Ila Sethi;
Nima Kokabi
BACKGROUND: The coronavirus disease 2019 (COVID-19) pandemic has made it more challenging for patients to undergo yttrium-90 (Y-90) radioembolization (RE). Same day Y-90 RE provides an opportunity to minimize logistical challenges and infection risk associated with COVID-19, thus improving patient access. AIM: To describe the use of same day Y-90 RE with routine single photon emission computed tomography/computed tomography (SPECT/CT) in order to optimize therapy. METHODS: All patients were selected for Y-90 RE through a multidisciplinary tumor board, and were screened and tested for COVID-19 infection per institutional protocol. A same day procedure was developed, consisting of angiography, imaging, and Y-90 resin particle delivery. Routine SPECT/CT after technetium-99m macroaggregated albumin (Tc-99m MAA) administration was performed for assessment of arterial supply, personalized dosimetry, and extrahepatic activity. Post-treatment Y-90 bremsstrahlung SPECT/CT was performed for confirmation of particle delivery, by utilization of energy windowing to limit signal from previously administered Tc-99m MAA particles. RESULTS: A total of 14 patients underwent same day Y-90 RE between March and June 2020. Mean lung shunt fraction was 6.13% (range 3.5%-13.1%). Y-90 RE was performed for a single lesion in 7 patients, while the remaining 7 patients had treatment of multifocal lesions. The largest lesion measured 8.3 cm. All patients tolerated the procedure well and were discharged the same day. CONCLUSION: Same day Y-90 RE with resin-based microspheres is feasible, and provides an opportunity to mitigate infection risk and logistical challenges associated with the COVID-19 pandemic and beyond. We recommend consideration of SPECT/CT, especially among patients with complex malignancies, for the potential to improve outcomes and eligibility of patients to undergo same day Y-90 RE.
It has been brought to our attention that the arrows in equation 10, equation 12, and equation 14 were not interpreted correctly in the above article in Seminars in Interventional Radiology , Volume 37, Number 5, 2020 (DOI https://doi.org/10.1055/s-0040-1720954 ). The equations have been corrected in the revised article.