Publication
Using 4DCT-ventilation to characterize lung function changes for pediatric patients getting thoracic radiotherapy
Downloadable Content
- Persistent URL
- Last modified
- 05/22/2025
- Type of Material
- Authors
- Language
- English
- Date
- 2018-06-26
- Publisher
- American Association of Physicists in Medicine
- Publication Version
- Copyright Statement
- © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
- License
- Final Published Version (URL)
- Title of Journal or Parent Work
- ISSN
- 1526-9914
- Volume
- 19
- Issue
- 5
- Start Page
- 407
- End Page
- 412
- Grant/Funding Information
- This work was partially funded by NCI/NIH grant R01CA200817 (YV, AF, MM, EC, RC, TG).
- Abstract
- Purpose: A form of lung functional imaging has been developed that uses 4DCT data to calculate ventilation (4DCT-ventilation). Because 4DCTs are acquired as standard-of-care to manage breathing motion during radiotherapy, 4DCT-ventilation provides functional information at no extra dosimetric or monetary cost. 4DCT-ventilation has yet to be described in children. 4DCT-ventilation can be used as a tool to help assess post-treatment lung function and predict for future clinical thoracic toxicities for pediatric patients receiving radiotherapy to the chest. The purpose of this work was to perform a preliminary evaluation of 4DCT-ventilation-based lung function changes for pediatric patients receiving radiotherapy to the lungs. Methods: The study used four patients with pre and postradiotherapy 4DCTs. The 4DCTs, deformable image registration, and a density-change-based algorithm were used to compute pre and post-treatment 4DCT-ventilation images. The post-treatment 4DCT-ventilation images were compared to the pretreatment 4DCT-ventilation images for a global lung response and for an intrapatient dose–response (providing an assessment for dose-dependent regional dose–response). Results: For three of the four patients, a global ventilation decline of 7–37% was observed, while one patient did not demonstrate a global functional decline. Dose–response analysis did not reveal an intrapatient dose–response from 0 to 20 Gy for three patients while one patient demonstrated increased 4DCT-ventilation decline as a function of increasing lung doses up to 50 Gy. Conclusions: Compared to adults, pediatric patients have unique lung function, dosimetric, and toxicity profiles. The presented work is the first to evaluate spatial lung function changes in pediatric patients using 4DCT-ventilation and showed lung function changes for three of the four patients. The early changes demonstrated with lung function imaging warrant further longitudinal work to determine whether the imaging-based early changes can be predicted for long-term clinical toxicity.
- Author Notes
- Keywords
- Research Categories
- Physics, Radiation
- Health Sciences, Oncology
Tools
- Download Item
- Contact Us
-
Citation Management Tools
Relations
- In Collection:
Items
| Thumbnail | Title | File Description | Date Uploaded | Visibility | Actions |
|---|---|---|---|---|---|
|
|
Publication File - tdgvj.pdf | Primary Content | 2025-03-19 | Public | Download |