Publication
Photon-Counting CT of the Brain: In Vivo Human Results and Image-Quality Assessment
Downloadable Content
- Persistent URL
- Last modified
- 05/23/2025
- Type of Material
- Authors
- Language
- English
- Date
- 2017-12-01
- Publisher
- AMER SOC NEURORADIOLOGY
- Publication Version
- Copyright Statement
- © 2017 by American Journal of Neuroradiology
- Final Published Version (URL)
- Title of Journal or Parent Work
- Volume
- 38
- Issue
- 12
- Start Page
- 2257
- End Page
- 2263
- Grant/Funding Information
- This study was supported by the National Institutes of Health intramural research program (ZIACL090019; ZIAEB000072; ZIANS003119) and a collaborative research agreement with Siemens (Erlangen, Germany).
- Abstract
- BACKGROUND AND PURPOSE: Photon-counting detectors offer the potential for improved image quality for brain CT but have not yet been evaluated in Vivo. The purpose of this study was to compare photon-counting detector CT with conventional energy-integrating detector CT for human brains. MATERIALS AND METHODS: Radiation dose-matched energy-integrating detector and photon-counting detector head CT scans were acquired with standardized protocols (tube voltage/current, 120 kV(peak)/370 mAs) in both an anthropomorphic head phantom and 21 human asymptomatic volunteers (mean age, 58.9 -8.5 years). Photon-counting detector thresholds were 22 and 52 keV (low-energy bin, 22-52 keV; high-energy bin, 52-120 keV). Image noise, gray matter, and white matter signal-To-noise ratios and GM-WM contrast and contrast-To-noise ratios were measured. Image quality was scored by 2 neuroradiologists blinded to the CT detector type. Reproducibility was assessed with the intraclass correlation coefficient. Energy-integrating detector and photon-counting detector CT images were compared using a paired t test and the Wilcoxon signed rank test. RESULTS: Photon-counting detector CT images received higher reader scores forGM-WMdifferentiation with lower image noise (all P- .001). Intrareader and interreader reproducibility was excellent (intraclass correlation coefficient, -0.86 and 0.79, respectively). Quantitative analysis showed 12.8%-20.6% less image noise for photon-counting detector CT. The SNR of photon-counting detector CT was 19.0%-20.0% higher than of energy-integrating detector CT forGMand WM. The contrast-To-noise ratio of photon-counting detector CT was 15.7% higher for GM-WM contrast and 33.3% higher for GM-WM contrast-To-noise ratio. CONCLUSIONS: Photon-counting detector brain CT scans demonstrated greater gray-white matter contrast compared with conventional CT. This was due to both higher soft-Tissue contrast and lower image noise for photon-counting CT.
- Author Notes
- Keywords
- Research Categories
- Health Sciences, Radiology
- Health Sciences, Pathology
Tools
- Download Item
- Contact Us
-
Citation Management Tools
Relations
- In Collection:
Items
| Thumbnail | Title | File Description | Date Uploaded | Visibility | Actions |
|---|---|---|---|---|---|
|
|
Publication File - vtbsq.pdf | Primary Content | 2025-05-08 | Public | Download |