Publication

Voxel-based dosimetry predicting treatment response and related toxicity in HCC patients treated with resin-based Y90 radioembolization: a prospective, single-arm study

Downloadable Content

Persistent URL
Last modified
  • 07/03/2025
Type of Material
Authors
    Nima Kokabi, Emory UniversityLinzi Arndt-Webster, Mt Sinai School of MedicineBernard Chen, University of Texas San AntonioDavid Brandon, Emory UniversityIla Sethi, Emory UniversityAmir Davarpanah, Emory UniversityJames Galt, Emory UniversityMohammad Elsayed, Memorial Sloan Kettering Cancer CenterZachary Bercu, Emory UniversityMircea Cristescu, Medical College of WisconsinS. Cheenu Kappadath, University of Texas MD Anderson Cancer CenterDavid Schuster, Emory University
Language
  • English
Date
  • 2023-01-18
Publisher
  • SPRINGER
Publication Version
Copyright Statement
  • © The Author(s) 2023
License
Final Published Version (URL)
Title of Journal or Parent Work
Volume
  • 50
Issue
  • 6
Start Page
  • 1743
End Page
  • 1752
Grant/Funding Information
  • The funding for the study was provided by RSNA Research Scholar Grant and Sirtex Medical Ltd., with X as the primary investigator.
Abstract
  • Background: There is an increasing body of evidence indicating Y90 dose thresholds for tumor response and treatment-related toxicity. These thresholds are poorly studied in resin Y90, particularly in hepatocellular carcinoma (HCC). Purpose: To evaluate the efficacy of prospective voxel-based dosimetry for predicting treatment response and adverse events (AEs) in patients with HCC undergoing resin-based Y90 radioembolization. Materials and methods: This correlative study was based on a prospective single-arm clinical trial (NCT04172714), which evaluated the efficacy of low/scout (555 MBq) activity of resin-based Y90 for treatment planning. Partition model was used with goal of tumor dose (TD) > 200 Gy and non-tumoral liver dose (NTLD) < 70 Gy for non-segmental therapies. Single compartment dose of 200 Gy was used for segmentectomies. Prescribed Y90 activity minus scout activity was administered for therapeutic Y90 followed by Y90-PET/CT. Sureplan® (MIM Software, Cleveland, OH) was used for dosimetry analysis. Treatment response was evaluated at 3 and 6 months. Receiver operating characteristic curve determined TD response threshold for objective response (OR) and complete response (CR) as well as non-tumor liver dose (NTLD) threshold that predicted AEs. Results: N = 30 patients were treated with 33 tumors (19 segmental and 14 non-segmental). One patient died before the first imaging, and clinical follow-up was excluded from this analysis. Overall, 26 (81%) of the tumors had an OR and 23 (72%) had a CR. A mean TD of 253 Gy predicted an OR with 92% sensitivity and 83% specificity (area under the curve (AUC = 0.929, p < 0.001). A mean TD of 337 Gy predicted a CR with 83% sensitivity and 89% specificity (AUC = 0.845, p < 0.001). A mean NTLD of 81 and 87 Gy predicted grade 3 AEs with 100% sensitivity and 100% specificity in the non-segmental cohort at 3- and 6-month post Y90, respectively. Conclusion: In patients with HCC undergoing resin-based Y90, there are dose response and dose toxicity thresholds directly affecting outcomes. Clinical trial number: NCT04172714.
Author Notes
Keywords
Research Categories
  • Health Sciences, Radiology
  • Health Sciences, Toxicology
  • Health Sciences, Medicine and Surgery

Tools

Relations

In Collection:

Items