Publication
Voxel-based dosimetry predicting treatment response and related toxicity in HCC patients treated with resin-based Y90 radioembolization: a prospective, single-arm study
Downloadable Content
- Persistent URL
- Last modified
- 07/03/2025
- Type of Material
- Authors
- Language
- English
- Date
- 2023-01-18
- Publisher
- SPRINGER
- Publication Version
- Copyright Statement
- © The Author(s) 2023
- License
- Final Published Version (URL)
- Title of Journal or Parent Work
- Volume
- 50
- Issue
- 6
- Start Page
- 1743
- End Page
- 1752
- Grant/Funding Information
- The funding for the study was provided by RSNA Research Scholar Grant and Sirtex Medical Ltd., with X as the primary investigator.
- Abstract
- Background: There is an increasing body of evidence indicating Y90 dose thresholds for tumor response and treatment-related toxicity. These thresholds are poorly studied in resin Y90, particularly in hepatocellular carcinoma (HCC). Purpose: To evaluate the efficacy of prospective voxel-based dosimetry for predicting treatment response and adverse events (AEs) in patients with HCC undergoing resin-based Y90 radioembolization. Materials and methods: This correlative study was based on a prospective single-arm clinical trial (NCT04172714), which evaluated the efficacy of low/scout (555 MBq) activity of resin-based Y90 for treatment planning. Partition model was used with goal of tumor dose (TD) > 200 Gy and non-tumoral liver dose (NTLD) < 70 Gy for non-segmental therapies. Single compartment dose of 200 Gy was used for segmentectomies. Prescribed Y90 activity minus scout activity was administered for therapeutic Y90 followed by Y90-PET/CT. Sureplan® (MIM Software, Cleveland, OH) was used for dosimetry analysis. Treatment response was evaluated at 3 and 6 months. Receiver operating characteristic curve determined TD response threshold for objective response (OR) and complete response (CR) as well as non-tumor liver dose (NTLD) threshold that predicted AEs. Results: N = 30 patients were treated with 33 tumors (19 segmental and 14 non-segmental). One patient died before the first imaging, and clinical follow-up was excluded from this analysis. Overall, 26 (81%) of the tumors had an OR and 23 (72%) had a CR. A mean TD of 253 Gy predicted an OR with 92% sensitivity and 83% specificity (area under the curve (AUC = 0.929, p < 0.001). A mean TD of 337 Gy predicted a CR with 83% sensitivity and 89% specificity (AUC = 0.845, p < 0.001). A mean NTLD of 81 and 87 Gy predicted grade 3 AEs with 100% sensitivity and 100% specificity in the non-segmental cohort at 3- and 6-month post Y90, respectively. Conclusion: In patients with HCC undergoing resin-based Y90, there are dose response and dose toxicity thresholds directly affecting outcomes. Clinical trial number: NCT04172714.
- Author Notes
- Keywords
- Research Categories
- Health Sciences, Radiology
- Health Sciences, Toxicology
- Health Sciences, Medicine and Surgery
Tools
- Download Item
- Contact Us
-
Citation Management Tools
Relations
- In Collection:
Items
| Thumbnail | Title | File Description | Date Uploaded | Visibility | Actions |
|---|---|---|---|---|---|
|
|
Publication File - w428g.pdf | Primary Content | 2025-05-28 | Public | Download |