Publication
Performance Evaluation of Calypso (R) 4D Localization and Kilovoltage Image Guidance Systems for Interfraction Motion Management of Prostate Patients
Downloadable Content
- Persistent URL
- Last modified
- 03/14/2025
- Type of Material
- Authors
-
-
Tomi Ogunleye, Emory UniversityPeter J Rossi, Emory UniversityAshesh B Jani, Emory UniversityTimothy Fox, Emory UniversityEric Elder, Emory University
- Language
- English
- Date
- 2009-01-01
- Publisher
- Hindawi Publishing Corporation
- Publication Version
- Copyright Statement
- ©2009 with author. Published by TheScientificWorld.
- License
- Final Published Version (URL)
- Title of Journal or Parent Work
- ISSN
- 2356-6140
- Volume
- 9
- Start Page
- 449
- End Page
- 458
- Abstract
- Prostate cancer represents a model site for advances in understanding inter- and intrafraction motion for radiotherapy. In this study, we examined the correlation of the electromagnetic transponder system/Calypso® 4D Localization System with conventional on-board imaging (OBI) using kilovoltage imaging. Initially using a quality assurance (QA) phantom and subsequently using data of seven patients, the vector distances between Calypso- and OBI-recorded shifts were compared using the t-test. For the 30 phantom measurements, the average differences between the measured Calypso offset and the calculated OBI shift were 0.4 ± 0.4, 0.2 ± 0.3, and 0.4 ± 0.3 mm in the lateral, longitudinal, and vertical directions, respectively (p = 0.73, p = 0.91, and p = 0.99, respectively), and the average difference vector for all sessions was 0.8 ± 0.4 mm. For the 259 patient measurements, the average differences between the measured Calypso offset and the calculated OBI shift were 0.7 ± 0.5, 1.1 ± 0.9, and 1.2 ± 0.9 mm in the lateral, longitudinal, and vertical directions, respectively (p = 0.45, p = 0.28, and p = 0.56, respectively), and the average difference vector for all sessions was 2.1 ± 1.0 mm. Our results demonstrated good correlation between Calypso and OBI. While other studies have explored the issue of Calypso/OBI correlation, our analysis is unique in our use of phantom validation and in our performing the patient analysis on an initial population prior to routine setup using Calypso without OBI. Implications for Calypso's role as a QA tool are discussed.
- Author Notes
- Keywords
- Research Categories
- Health Sciences, Radiology
- Health Sciences, Oncology
Tools
- Download Item
- Contact Us
-
Citation Management Tools
Relations
- In Collection:
Items
| Thumbnail | Title | File Description | Date Uploaded | Visibility | Actions |
|---|---|---|---|---|---|
|
|
Publication File - s8p4z.pdf | Primary Content | 2025-03-08 | Public | Download |