Publication

A New CT Prostate Segmentation for CT-Based HDR Brachytherapy

Downloadable Content

Persistent URL
Last modified
  • 02/20/2025
Type of Material
Authors
    Xiaofeng Yang, Emory UniversityPeter Rossi, Emory UniversityTomi Ogunleye, Emory UniversityAshesh Jani, Emory UniversityWalter Curran, Emory UniversityTian Liu, Emory University
Language
  • English
Date
  • 2014-01-01
Publisher
  • Emory University Libraries
Publication Version
Copyright Statement
  • © 2014 SPIE.
Final Published Version (URL)
Title of Journal or Parent Work
Conference or Event Name
  • Conference on Medical Imaging - Image-Guided Procedures, Robotic Interventions, and Modeling
Volume
  • 9036
Start Page
  • 90362K
End Page
  • 90362K
Grant/Funding Information
  • This research is supported in part by the Department of Defense (DoD) Prostate Cancer Research Program (PCRP) Award W81XWH-13-1-0269 and National Cancer Institute (NCI) Grant CA114313.
Abstract
  • High-dose-rate (HDR) brachytherapy has become a popular treatment modality for localized prostate cancer. Prostate HDR treatment involves placing 10 to 20 catheters (needles) into the prostate gland, and then delivering radiation dose to the cancerous regions through these catheters. These catheters are often inserted with transrectal ultrasound (TRUS) guidance and the HDR treatment plan is based on the CT images. The main challenge for CT-based HDR planning is to accurately segment prostate volume in CT images due to the poor soft tissue contrast and additional artifacts introduced by the catheters. To overcome these limitations, we propose a novel approach to segment the prostate in CT images through TRUS-CT deformable registration based on the catheter locations. In this approach, the HDR catheters are reconstructed from the intra-operative TRUS and planning CT images, and then used as landmarks for the TRUS-CT image registration. The prostate contour generated from the TRUS images captured during the ultrasound-guided HDR procedure was used to segment the prostate on the CT images through deformable registration. We conducted two studies. A prostate-phantom study demonstrated a submillimeter accuracy of our method. A pilot study of 5 prostate-cancer patients was conducted to further test its clinical feasibility. All patients had 3 gold markers implanted in the prostate that were used to evaluate the registration accuracy, as well as previous diagnostic MR images that were used as the gold standard to assess the prostate segmentation. For the 5 patients, the mean gold-marker displacement was 1.2 mm; the prostate volume difference between our approach and the MRI was 7.2%, and the Dice volume overlap was over 91%. Our proposed method could improve prostate delineation, enable accurate dose planning and delivery, and potentially enhance prostate HDR treatment outcome.
Author Notes
Keywords
Research Categories
  • Engineering, Biomedical
  • Health Sciences, Oncology
  • Health Sciences, Radiology

Tools

Relations

In Collection:

Items