Publication

Albumin adsorption onto surfaces of urine collection and analysis containers

Downloadable Content

Persistent URL
Last modified
  • 03/05/2025
Type of Material
Authors
    Mary K. Robinson, Centers for Disease Control & PreventionSamuel P. Caudill, Centers for Disease Control & PreventionDavid D Koch, Emory UniversityJames C Ritchie, Emory UniversityGlen Hortin, Quest DiagnosticsJohn H. Eckfeldt, University of MinnesotaSverre Sandberg, Haukeland UniversityDesmond Williams, Centers for Disease Control & PreventionGary Myers, American Association for Clinical ChemistryW. Greg Miller, Virginia Commonwealth University
Language
  • English
Date
  • 2014-04-20
Publisher
  • Elsevier
Publication Version
Copyright Statement
  • © 2014 Elsevier B.V. Published by Elsevier B.V. All rights reserved.
Final Published Version (URL)
Title of Journal or Parent Work
ISSN
  • 0009-8981
Volume
  • 431
Start Page
  • 40
End Page
  • 45
Supplemental Material (URL)
Abstract
  • Background: Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. Methods: We added 125 I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Results: Adsorption of urine albumin (UA) at 5-6. mg/l was < . 0.9%; and at 90. mg/l was < . 0.4%. Adsorption was generally less at pH. 8 than pH. 5 but only 3 cases had p. < . 0.05. Adsorption from 11 unaltered urine samples with albumin 5-333. mg/l was < . 0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100. ml and 2. l collection containers, and to instrument sample cups and showed < . 1% change in concentration at 5. mg/l and < . 0.5% change at 20. mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2-28%) was larger than that from urine. Conclusions: Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was < . 1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators.
Author Notes
  • Corresponding author at: PO Box 286, Richmond, VA 23298-0286, United States. Tel.: +1 804 828 0375; fax: +1 804 828 0353. gmiller@vcu.edu (W.G. Miller)
Keywords
Research Categories
  • Health Sciences, Pathology
  • Health Sciences, Medicine and Surgery

Tools

Relations

In Collection:

Items