Publication
Measurement of Ocular Compliance Using iPerfusion
Downloadable Content
- Persistent URL
- Last modified
- 05/14/2025
- Type of Material
- Authors
- Language
- English
- Date
- 2019-10-25
- Publisher
- Frontiers Media SA
- Publication Version
- Copyright Statement
- © 2019 Sherwood, Boazak, Feola, Parker, Ethier and Overby.
- License
- Final Published Version (URL)
- Title of Journal or Parent Work
- Volume
- 7
- Issue
- OCT
- Start Page
- 276
- End Page
- 276
- Grant/Funding Information
- National Institutes of Health - R21EY026685
- RR&D Service Career Development Award - RX002342
- National Institutes of Health - EY022359
- National Institutes of Health - EY019696
- Bright Focus Foundation - G2015145
- Royal Academy of Engineering Research Fellowship, UK
- Supplemental Material (URL)
- Abstract
- The pressure-volume relationship of the eye is determined by the biomechanical properties of the corneoscleral shell and is classically characterised by Friedenwald’s coefficient of ocular rigidity or, alternatively, by the ocular compliance (OC), defined as dV/dP. OC is important in any situation where the volume (V) or pressure (P) of the eye is perturbed, as occurs during several physiological and pathological processes. However, accurately measuring OC is challenging, particularly in rodents. We measured OC in 24 untreated enucleated eyes from 12 C57BL/6 mice using the iPerfusion system to apply controlled pressure steps, whilst measuring the time-varying flow rate into the eye. Pressure and flow data were analysed by a “Discrete Volume” (integrating the flow trace) and “Step Response” method (fitting an analytical solution to the pressure trace). OC evaluated at 13 mmHg was similar between the two methods (Step Response, 41 [37, 46] vs. Discrete Volume, 42 [37, 48] nl/mmHg; mean [95% CI]), although the Step Response Method yielded tighter confidence bounds on individual eyes. OC was tightly correlated between contralateral eyes (R2 = 0.75, p = 0.0003). Following treatment with the cross-linking agent genipin, OC decreased by 40 [33, 47]% (p = 0.0001; N = 6, Step Response Method). Measuring OC provides a powerful tool to assess corneoscleral biomechanics in mice and other species.
- Author Notes
- Keywords
- Research Categories
- Engineering, Biomedical
- Health Sciences, Medicine and Surgery
Tools
- Download Item
- Contact Us
-
Citation Management Tools
Relations
- In Collection:
Items
| Thumbnail | Title | File Description | Date Uploaded | Visibility | Actions |
|---|---|---|---|---|---|
|
|
Publication File - vh6c1.pdf | Primary Content | 2025-04-11 | Public | Download |