Publication

Acetazolamide-augmented dynamic BOLD (aczBOLD) imaging for assessing cerebrovascular reactivity in chronic steno-occlusive disease of the anterior circulation: An initial experience

Downloadable Content

Persistent URL
Last modified
  • 02/20/2025
Type of Material
Authors
    Junjie Wu, Emory UniversitySeena Dehkharghani, Emory UniversityFadi Nahab, Emory UniversityDeqiang Qiu, Emory University
Language
  • English
Date
  • 2017-01-01
Publisher
  • Elsevier
Publication Version
Copyright Statement
  • © 2016 The Authors.
License
Final Published Version (URL)
Title of Journal or Parent Work
ISSN
  • 2213-1582
Volume
  • 13
Start Page
  • 116
End Page
  • 122
Abstract
  • The purpose of this study was to measure cerebrovascular reactivity (CVR) in chronic steno-occlusive disease using a novel approach that couples BOLD imaging with acetazolamide (ACZ) vasoreactivity (aczBOLD), to evaluate dynamic effects of ACZ on BOLD and to establish the relationship between aczBOLD and dynamic susceptibility contrast (DSC) perfusion MRI. Eighteen patients with unilateral chronic steno-occlusive disease of the anterior circulation underwent a 20-min aczBOLD imaging protocol, with ACZ infusion starting at 5 min of scan initiation. AczBOLD reactivity was calculated on a voxel-by-voxel basis to generate CVR maps for subsequent quantitative analyses. Reduced CVR was observed in the diseased vs. the normal hemisphere both by qualitative and quantitative assessment (gray matter (GM): 4.13% ± 1.16% vs. 4.90% ± 0.98%, P = 0.002; white matter (WM): 2.83% ± 1.23% vs. 3.50% ± 0.94%, P = 0.005). In all cases BOLD signal began increasing immediately following ACZ infusion, approaching a plateau at ~ 8.5 min after infusion, with the tissue volume of reduced augmentation increasing progressively with time, peaking at 2.60 min (time range above 95% of the maximum value: 0–4.43 min) for the GM and 1.80 min (time range above 95% of the maximum value: 1.40–3.53 min) for the WM. In the diseased hemisphere, aczBOLD CVR significantly correlated with baseline DSC time-to-maximum of the residue function (Tmax) (P = 0.008 for the WM) and normalized cerebral blood flow (P = 0.003 for the GM, and P = 0.001 for the WM). AczBOLD provides a novel, safe, easily implementable approach to CVR measurement in the routine clinical environments. Further studies can establish quantitative thresholds from aczBOLD towards identification of patients at heightened risk of recurrent ischemia and cognitive decline.
Author Notes
  • Corresponding author: D. Qiu, Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1364 Clifton Road NE CG06, Atlanta, GA 30322, United States. E-mail address: dqiu3@emory.edu.
Keywords
Research Categories
  • Health Sciences, Medicine and Surgery
  • Biology, Neuroscience
  • Health Sciences, Radiology

Tools

Relations

In Collection:

Items