Publication
Development of Flexible Ion-Selective Electrodes for Saliva Sodium Detection
Downloadable Content
- Persistent URL
- Last modified
- 05/20/2025
- Type of Material
- Authors
- Language
- English
- Date
- 2021-03-01
- Publisher
- MDPI
- Publication Version
- Copyright Statement
- © 2021 by the authors.
- License
- Final Published Version (URL)
- Title of Journal or Parent Work
- Volume
- 21
- Issue
- 5
- Start Page
- 1
- End Page
- 11
- Grant/Funding Information
- We acknowledge the support from the Marcus Foundation, the Georgia Research Alliance, and the Georgia Tech Foundation through their support of the Marcus Center for Therapeutic Cell Characterization and Manufacturing (MC3M) at Georgia Tech.
- This study was partially supported by a faculty research grant from Yonsei University College of Medicine (6-2019-0169). Some of the materials used in the device were partially supported by the MSIT (Ministry of Science, ICT), Korea, under the High-Potential Individuals Global Training Program) (IITP-2020-0-01517) supervised by the IITP (Institute for Information & Communications Technology Planning & Evaluation).
- Supplemental Material (URL)
- Abstract
- Saliva can be used for health monitoring with non-invasive wearable systems. Such devices, including electrochemical sensors, may provide a safe, fast, and cost-efficient way of detecting target ions. Although salivary ions are known to reflect those in blood, no available clinical device can detect essential ions directly from saliva. Here, we introduce an all-solid-state, flexible film sensor that allows highly accurate detection of sodium levels in saliva, comparable to those in blood. The wireless film sensor system can successfully measure sodium ions from a small volume of infants’ saliva (<400 µL), demonstrating its potential as a continuous health monitor. This study includes the structural characterization and error analysis of a carbon/elastomer-based ion-selective electrode and a reference electrode to confirm the signal reliability. The sensor, composed of a pair of the electrodes, shows good sensitivity (58.9 mV/decade) and selectivity (log K = −2.68 for potassium), along with a broad detection range of 5 × 10−5 ≈ 1 M with a low detection limit of 4.27 × 10−5 M. The simultaneous comparison between the film sensor and a commercial electrochemical sensor demonstrates the accuracy of the flexible sensor and a positive correlation in saliva-to-blood sodium levels. Collectively, the presented study shows the potential of the wireless ion-selective sensor system for a non-invasive, early disease diagnosis with saliva.
- Author Notes
- Keywords
- Research Categories
- Engineering, Biomedical
- Engineering, Mechanical
Tools
- Download Item
- Contact Us
-
Citation Management Tools
Relations
- In Collection:
Items
| Thumbnail | Title | File Description | Date Uploaded | Visibility | Actions |
|---|---|---|---|---|---|
|
|
Publication File - vxh77.pdf | Primary Content | 2025-05-19 | Public | Download |